OSU-250046 Evans Lab 1969 Addition Demolition
Complete demolition of north wing of Evans Lab, the 1969 (northern most) addition of the facility. The remaining site will become temporary green space.
Utilities serving adjacent wings will be maintained, including but not limited to natural gas, heating and domestic hot water, steam, domestic cold water, electric, fire alarm and ERRCS systems, and will be capped/terminated at appropriate locations to allow for re-use in subsequent project phases.
A metal panel wall enclosure and interior hollow metal doors will be added to the remaining facility.
| 05/21/2026 06:00 PM UTC |
|
OSU-250037 Roof Renewal FY25-26 REBID
Roof Renewal FY25-26
SBS Modified Bitumen Roof Replacement at Physical Activity and Education Services Building, Parks Hall and Scott Laboratory.
PVC Membrane Roof Replacement at Independence Hall.
Minor electrical and mechanical work to facilitate re-roofing, including removal of an abandoned chiller
| 05/22/2026 06:00 PM UTC |
|
OSU-240264, James - Envelope Remediation
The Work primarily includes replacement of joint sealants, gasketing, and cleaning and sealing of existing masonry. See Specification section 01 10 00 for detailed description of the Work.
| 05/28/2026 06:00 PM UTC |
|
OSU-255557, Morehouse Medical Plaza - 2400 GIM refresh
Phased renovation of selected areas within the Morehouse Medical Plaza, Suite 2400 General Internal Medicine Suite.
| 06/05/2026 06:00 PM UTC |
|
OSU-265050, Ackerman Rd, 660 - chiller replacement
Replacement of water-cooled chiller, cooling tower, and miscellaneous related modifications.
| 06/09/2026 06:00 PM UTC |
|
OSU-230109 Emergency Generator Replacements FY23-24 REBID
Provide new diesel generator with sub-base fuel tank, and multiple automatic transfer switches for the separation of life-safety and stand-by electrical distribution systems. The generator will be located exterior of Mershon Auditorium and Wexner Center. Provide required site work, including modification of existing planters and new metal fence for installation of generator.
| 06/18/2026 05:00 PM UTC |
| Number | Deadline |
|---|---|
|
OSU-240693 - PRB - Quantum Physics Lab Mechanical Upgrades
A 1,620 SF interior renovation of two research labs at the basement level of the Physics Research Building on the OSU Columbus Campus This project includes minor demolition, construction of new interior partitions, new finishes, and associated mechanical, electrical, plumbing, and fire protection work.
| 03/11/2025 06:00 PM UTC |
|
OSU-190066 HVAC Replacements FY 2019 BP 2
Davis Heart and Lung Institute:
Replacement of HVAC controls on Air Handling and HVAC Equipment with new DDC controls.
| 03/07/2025 06:00 PM UTC |
|
OSU-230420 Pressey Rms 042T and 044T ADA Upgrades
The renovation of existing toilet rooms into compliant ADA toilet rooms. Renovation will include modification to architectural finishes, electrical, fire alarm, and plumbing systems. Included is the installation of one adult changing station and associated structural reinforcement.
| 02/27/2025 07:00 PM UTC |
|
OSU-230107 BP 1 Electrical Renovation FY 23-24 REBID
Replace main electrical distribution equipment in The Ohio State University’s Caldwell Laboratory Building including switchboards and panelboards.
| 02/20/2025 06:00 PM UTC |
|
OSU-230106 Plumbing Renovations FY23-24 BioScience
This is a Rebid. New domestic water and fire backflow preventors in a new location. Backfeed existing systems. Replacement of existing galvanized steel cold water piping throughout the facility. Installation of new piping prior to demolition of active mains. Abatement related to installation and demolition of work. Hazardous containment in areas of known hazardous fireproofing. Finishes associated with access and pipe replacement. All work required for installation in an active and occupied facility.
| 02/10/2025 06:00 PM UTC |
|
OSU-250003 - Ohio Stadium - Concession Stand Heaters
This project is for the installation of heaters within concession
spaces that provide heat during winter events. The current scope of the project includes the installation of 34 electrically powered heaters.
| 12/30/2024 07:00 PM UTC |
|
OSU-230431 1 Evans Hall Chiller Replacement REBID
Removal of existing chiller, providing new automatic propylene glycol feeder, providing 40% propylene glycol solution to fill system, installation of University purchased packaged chiller and transformer, provide concrete equipment pads, louvered fencing, site restoration, 200 gallon buffer tank, extending chilled water piping through roof to new chiller location, providing electric and controls from second floor mechanical room to University purchased chiller and transformer location outside on grade.
| 12/12/2024 07:00 PM UTC |
|
OSU-230686 Veterinary Medical Center AHU-1 & AHU-2 Damper Replacement
Replacement of the existing OA, RA, and EA dampers and damper actuators serving AHU-1 and AHU-2. Addition of freeze protection pumps and associated piping, valves and accessories for the pre-heat coils in AHU-1 and AHU-2. Integration of the new freeze protection pumps into the existing BAS.
| 12/12/2024 06:00 PM UTC |
|
Project OSU-230111 Road/Bridge Renewal FY23/24 RB 4
The planned scope of work includes rehabilitation of two bridges on The Ohio State University’s Main Campus: Woody Hayes over Olentangy River Road, Woody Hayes over Olentangy River. Maintenance level repairs generally include concrete patching/repairs, concrete walk repairs/replacement, joint and crack sealing, and deck sealing and repairs.
| 12/11/2024 07:00 PM UTC |
|
OSU-230499 Tunnel Rehabilitation Phase I BP 2
The project consists of the removal and replacement of the North McCracken tunnel roof, the complete removal of the North McCracken tunnel bypass, and the inspection and patching of tunnels located underneath building footprints. The Project will also construct a new steam line within the North McCracken Tunnel. Under the Alternate 1 scope of work, a new water main will be constructed from the east end of the Oval to the west end and then up to the Cockins/Dulles loading dock area. The Alternate 2 scope of work provides alternate restoration methods to the North Oval Mall.
| 12/06/2024 06:00 PM UTC |
You have successfully created your Digital ID. It has been installed to your browser.
We recommend that you also download a backup of your Digital ID and save it securely to an external storage location, as this file must be installed again if you intend to use a different browser or computer for bidding, document signing, and solicitation management.
Learn more about managing your Digital ID.Click Install Backup ID to use your Digital ID in this location.
If you don't have a copy of your backup ID, but you have access to the computer and browser where it was first created, you can still create a backup ID to install to this location. For help, see how to back up your Digital ID.
If you don't have access to the original computer and browser, you can create a new Digital ID below.