Iowa State University
700 Wallace Rd Gen Serv/Room 200, Ames, IA 50011-4012
(515) 294-0366
700 Wallace Rd Gen Serv/Room 200, Ames, IA 50011-4012
(515) 294-0366
Name * | Description | |
---|---|---|
Number | Deadline |
---|---|
CP1271058-Hamilton Hall-Room 0002-Remodel
This project will remodel the existing studio space. The scope of work includes, but is not limited to, removing a window from the vestibule wall and installing it in the control room wall; cutting an opening in the vestibule wall for a new window; cutting a large view window into the interior vestibule wood door; and painting all walls, door and window frames. This project also includes numerous lighting additions and upgrades, as well as a large amount of AV equipment.
| 08/21/2025 07:01 PM UTC |
Number | Deadline |
---|---|
CP002511 - Zaffarano Physics Addition-Fan Coil Replacement-Phase 3
The project consists of, but is not limited to, the removal and replacement of fifty-five (55) fan coil units and accessories. Complete installation per each unit(s) in a single room to be completed in three (3) work days. Work involves installation of new unit and accessories, insulation of piping, ductwork, and completion of control work. Moving and reinstallation of furniture or equipment by Owner, Contractor to coordinate.
| 10/23/2018 07:01 PM UTC |
CP002411 - Curtiss Hall-Second Floor Renovation
The Project consists of the alteration of public hallways and office areas on second floor of Curtiss Hall, including the addition of a single use restroom, lactation room, and custodian’s closet.
| 09/27/2018 07:01 PM UTC |
CP002225 - Student Innovation Center-Issuance 5-Food Service Rebid
The project consists of, but is not limited to, a 138,973 sf new building, that includes a basement and four (4) floors above grade. Work includes food service equipment for a café and demonstration kitchen.
| 09/18/2018 07:01 PM UTC |
CP002532 - Veterinary Medical Research Institute-Buildings 1-6 Condensate Returns Replacement
The project consists of, but is not limited to, installation of a new low-pressure condensate return system between buildings 1 through 6 at Veterinary Medical Research Institute (VMRI). Work includes abandonment or removal or existing condensate lines, installation of new condensate return piping between buildings, connection of new piping to existing service inside each building, and removal and replacement of concrete sidewalk as needed for installation.
| 09/13/2018 07:01 PM UTC |
CP002423 - Utilities-Power Plant-Fire Alarm System Improvements
The project consists of, but is not limited to, furnish and install a new Addressable Fire Alarm System throughout the Power Plant including, misc. cutting and patching, patch painting, removal of existing fire alarm system, new fire alarm control panel, new master annunciators, new automatic detection devices, new audio/visual signals, new connections to existing wet-pipe deluge systems, wiring, conduit and other related electrical work.
| 08/30/2018 07:01 PM UTC |
CP002528-BioCentury Research Farm - HST Building Roof Replacement & Interior Remodel-Interior Remodel
The project consists of, but is not limited to, providing transportation, equipment, materials, construction, and services necessary to remodel the interior of a pre-engineered steel farm building. Work will include spray foam insulation, steel wall liner, miscellaneous carpentry, mechanical, and electrical work.
| 08/28/2018 07:01 PM UTC |
CP002491 - Bessey Hall-Roof Replacement-Sections A-C, F and H
The project consists of, but is not limited to, the removal and replacement of roof sections A, B, C, F, & H due to the continual and ongoing maintenance, re-engineering Sections A,B,C,F & H to alleviate roof leak issues, replacement of swamp cooler curb and all roofing material down to the roof deck, removal of all abandoned roof equipment, repair sections properly prior to roof replacement, and replacement of all flashings.
| 08/23/2018 07:01 PM UTC |
CP002501-Communications Building-Second Floor Remodel-Iowa Public Radio
The project consists of, but is not limited to, remodeling existing offices and conference space, ceiling replacement, flooring installation, painting, lighting, doors and associated hardware, lighting upgrades, millwork, mechanical, electrical, plumbing, and access controls.
| 08/07/2018 07:01 PM UTC |
CP002528-BioCentury Research Farm - HST Building Roof Replacement
The project consists of, but is not limited to, providing transportation, equipment, materials, construction, and services necessary to install a new structural retrofit roof sub-framing system, insulation, and new metal standing seam roof over an existing building roof.
| 07/19/2018 07:01 PM UTC |
CP002485 - Department of Residence-Helser Residence Hall-Elevator Improvements
The project consists of, but is not limited to, modernization of the current freight elevator into a passenger elevator, construction of new elevator penthouse and mechanical room, and associated structural alterations for penetration of roof deck for new construction.
| 06/07/2018 07:01 PM UTC |
You have successfully created your Digital ID. It has been installed to your browser.
We recommend that you also download a backup of your Digital ID and save it securely to an external storage location, as this file must be installed again if you intend to use a different browser or computer for bidding, document signing, and solicitation management.
Learn more about managing your Digital ID.Click Install Backup ID to use your Digital ID in this location.
If you don't have a copy of your backup ID, but you have access to the computer and browser where it was first created, you can still create a backup ID to install to this location. For help, see how to back up your Digital ID.
If you don't have access to the original computer and browser, you can create a new Digital ID below.